Isıcam Systems, Produced by Şen Ortaklar Cam LTD STI who have achieved superior quality standards, under the franchise agreement and the supervision of Şişecam Flat Glass.

Advantages

  • Heat control / Solar control
  • Sound control
  • Safety and security

with its 3 different series and additional features.

Isıcam Sytems K Series: This series is manufactured from high quality heat and solar control coated Low-E Glass. Compared to ordinary double glazing units, it reduces heat loss by 50% providing maximum thermal insulation in winter and it reduces solar heat gains by 40%, thusly reducing cooling costs in summer.

Isıcam Systems S Series: This series is manufactured from high quality heat control coated Low-E Glass. Compared to ordinary double glazing, it reduces heat loss by 50%, thus decreasing heating expenses and saving energy during the winter.

Isıcam Systems C Series: This Series is the classical series which provides insulation at a standard level through the Isıcam’s assurance.

 

Isıcam Systems are produced by Şen Ortaklar Cam LTD STI through the supervision of Flat Glass in which Flat Glass’s glass products are used in production of double glazing insulating units through modern technologies.

Technical Features

Isıcam system is an insulating glass unit produced by Isıcam Authorized Producers through the supervision of Şişecam Düzcam in which convenient dry air or gases are present between two or more glass panes.

Performance Table

Isıcam Systems Configuration Daylight (EN 410) Solar Energy (EN 410) Thermal Conductivity (U) W/m2K (EN 673)
Transmittance % Reflectance Outdoor % Solar Factor % Shading Coefficient Dry Air Argon
4+12+4 80 14 75 0,86 2,9 2,7
4+16+4 2,7 2,6
S 4+12+4 79 12 56 0,64 1,6 1,3
4+16+4 1,3 1,1
K 4+12+4 71 10 44 0,51 1,6 1,3
4+16+4 1,3 1,1

Isıcam conforms to the following national / international standards

TS 3539 EN 1279 Glass in building – Insulating Glass Units

Raw materials conform to the following national / international standards

  •  Glass
    • TS EN 572/2 Glass in building – Basic soda lime silicate glass products – Part 2: Float Glass
    • TS EN 572/8 Glass in building – Basic soda lime silicate glass products – Part 8: Supplied and final cut sizes
    • TS EN 572/5 Glass in building – Basic soda lime silicate glass products – Part 5: Patterned glass
    • TS EN 12150 Glass in building – Thermally toughened soda lime silicate safety glass
    • TS EN 1863 Glass in building – Heat strengthened soda lime silicate glass
    • TS EN ISO12543 Glass in building – Laminated glass and laminated safety glass
    • TS EN 1096 Glass in building – Coated glass
    • EN 14179 Glass in building – Heat soaked thermally toughened soda lime silicate safety glass
  •  Other raw materials
    • Butyl, polysulfide, silicon, polyurethane, dehumidifier and spacing bar raw materials provided in the Isıcam Approved Material List, issued by Şişecam Düzcam, are used in the manufacturing of Isıcam. If the sealant materials utilized are replaced with other brands of sealant materials, provided that they are included in Isıcam Approved Material List, the conditions of substitution in Article 4.2.2. of TS 3539 EN1279-4 standard must be realized.

 

Isıcam quality

  •  Isıcam’s optical and visual quality
    •  Spot faults

Isıcam’s optic and visual quality is defined as TS EN 1279/1. Accordingly, the optic and visual quality given in the related standards of glass that constitute Isıcam are applicable.

The appearance and quality conditions of single plates are at a level that do not exceed the maximum error limit; therefore, there is no need to look for an additional requirement in this regard. Nevertheless, a higher acceptance level may be included in a quality agreement between the customer and the isolation glass unit manufacturer.

Details on optic and apparent quality inherent to ISICAM’s natural structure and/or physical specifications are provided in TS EN 1279/1 Annex C.

For Isıcam spot faults, the acceptance levels applied to glass applicable to market supply and end cutting dimensions for TS EN 572/8.

Acceptance levels for spot faults at end cutting dimensions for the float glass used in Isıcam:

Defect class Surface area of the glass plate (S), m²
S ≤ 5 5 < S ≤ 10 10 < S ≤ 20
A Not required
B 1 2 4
C Unacceptable 1 1
D Unacceptable
Distance between Class B defects should be less than 500mm.


Spot fault groups

Group Size of spot faults cores (mm)
A Glass thickness greater than 0.2mm and smaller than or equal to 0.5mm
B Glass thickness greater than 0.5mm and smaller than or equal to 1.0mm
C Glass thickness greater than 1.0mm and smaller than or equal to 3.0mm
D Greater than 3.0mm

The tolerances in TS EN 1096 Coated Glass Standard are applicable for Isıcam units manufactured with above-line reflective solar control coated glass.

    •  Linear defects (scratches and scrapings)

Isıcam’s optic and visual quality is defined by TS EN 1279/1. Accordingly, the optic and visual quality given in the related standards of glass that constitute Isıcam are applicable.

The appearance and quality conditions of single panes are at a level which would not exceed the maximum error limit; therefore, there is no need to look for an additional requirement in this regard. Nevertheless, a higher acceptance level may be included in a quality agreement between the customer and the isolation glass unit manufacturer.

Details on optic and apparent quality inherent to ISICAM’s natural structure and/or physical specifications are detailed in TS EN 1279/1 Annex C.

Any linear defects are not allowed as detailed in TS EN 572/8 Standard for Glass Marketing and End-Cutting Dimensions.

In TS EN 572/8, although an observation distance is given as 2m for the identification of both standard spot and superficial defects, the observation distance will be considered as 1m as per Isıcam standard. Therefore, the defects mentioned in TS EN 572/8 and TS EN 1096 are considered a mistake when they are identified at a 1m observation distance.

    •  Other defects

As you are aware, the separating material (lucite powder, paper etc.) prevents friction of glass units when placed top of each other, and protects the glass surface against humidity and temperature variations. The powder or paper placed between the glass panes has a compound structure that does not damage the chemical structure of the glass; neither powder nor paper is used. The grain size is also at least as important as the chemical structure of the powder. Therefore, the paper and powder to be inserted between glass units are distinctively chosen and used after being checked.

Corrosion error occurs upon the damage of the chemical structure of glass through the condensation of humidity present in air or through wetting of spot-worn surfaces that occur upon friction of glass panes. Corrosion defect is noted as white spots on glass in a later stage. It may not be observed with the naked eye at the beginning stage. Therefore, corrosion should be checked by keeping stream onto the glass surfaces at a close distance from time to time. Corrosion defects are not allowed on an Isıcam unit. Therefore, care should be taken during storage and handling of glass packages. Particularly in winter season when glass packages are transferred from outside to inside of the factory, packages should not be opened and processed until the product has reached ambient temperature.

There should not be any dust, stain, sealant stains, finger prints etc. on the internal surfaces of glass panes.

Standard Thicknesses and Dimensions

Dimensional tolerances of Isıcam (according to EN 1279):

Dimension Sheet glass panes Dimesion Tolerance
Length smaller than or equal to 3m Glass thickness smaller than or equal to 6mm ± 2mm
Glass thickness greater than 6mm ± 3mm
Length greater than 3m Glass thickness smaller than or equal to 6mm ± 3mm
Glass thickness greater than 6mm ± 4mm
Glass with a minimum of one plate tempered or heat strengthened
Length smaller than or equal to 3m Glass thickness smaller than or equal to 6mm ± 3mm
Length greater than 3m Glass thickness smaller than or equal to 6mm ± 4mm

 

Glass with a minimum of one laminated plate
Length smaller than or equal to 1.5m Total laminated glass thickness smaller than or equal to 16mm ± 3mm
Total laminated glass thickness greater than 16mm ± 4mm
Length greater than 1.5m and
smaller than or equal to 2.5m
Total laminated glass thickness smaller than or equal to 16mm ± 4mm
Total laminated glass thickness greater than 16mm ± 5mm
Length greater than 2.5m Total laminated glass thickness smaller than or equal to 16mm ± 5mm
Total laminated glass thickness greater than 16mm ± 6mm
Isıcam unit’s thickness tolerances
1st plate 2nd plate Thickness tolerances
A Float glass or coated glass
Thickness < 6mm Thickness > 6mm
Float glass or coated glass
and thickness < 6mm and/or thickness > 6mm
± 1 mm
± 1,5 mm
B Float glass or coated glass Tempered or heat strengthened float or coated glass ± 2 mm
C Float glass or coated glass Patterned glass ± 1,5 mm
D Float or Patterned glass Laminated glass ± 1.5 mm
E Tempered or heat strengthened glass Tempered or heat strengthened glass ± 2,5 mm
F Tempered or heat strengthened glass Patterned glass ± 2 mm
G Tempered or heat strengthened glass Laminated glass ± 2 mm
H Patterned glass Laminated glass ± 1,5 mm
İ Laminated glass Laminated glass ± 1,5 mm
Offset tolerance between Isıcam Unit’s plates

The offset quantity between the lower and higher Isıcam glass plates may be a maximum of 1.5mm.